Use this class to setup M-Bus slave devices and to exchange data with them.

Properties

  • 1. Logical Name
    Logical name of the object.
  • 2. M-Bus Port reference
    Reference to M-Bus master port setup object.
  • 3. Capture definition
    Provides the capture definition for M-Bus slave devices.
  • 4. Capture period
    Capture period in seconds.
  • 5. Primary address
    The primary address of the M-Bus slave device.
  • 6. Identification number
    The identification Number element of the data header.
  • 7. Manufacturer ID
    The manufacturer Identification element of the data header.
  • 8. Version
    The version element of the data header.
  • 9. Device type
    The device type identification element.
  • 10. Access number
    The access number element of the data header.
  • 11. Status
    The Status byte element of the data header.
  • 12. Alarm
    The alarm state.

Actions

  • 1. Slave install
    Installs a unconfigured slave device.
  • 2. Slave deinstall
    De-installs the slave device.
  • 3. Capture
    Capture values.
  • 4. Reset alarm
    Reset alarm state of the M-Bus slave device.
  • 5. Synchronize clock
    Synchronize the clock of the M-Bus slave device.
  • 6. Data send
    Send data to the M-Bus slave device.
  • 7. Set encryption key
    Sets encryption key to be used with the M-Bus slave device.
  • 8. Transfer key
    Transfers an encryption key to the M-Bus slave.
.

Book traversal links for M-Bus Client

  • Limiter
  • Up
  • M-Bus master port setup
  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv4 setup
  • IPv6 setup
  • Image transfer
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register activation
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Utility tables
  • Manufacturer custom objects

Hire Us!

Latest Releases

  • Wed, 12/10/2025 - 08:45
    gurux.dlms.java 4.0.85
  • Tue, 12/02/2025 - 10:21
    gurux.dlms.c 9.0.2512.0201
  • Mon, 12/01/2025 - 13:55
    Gurux.DLMS.Python 1.0.193
  • Thu, 11/13/2025 - 15:23
    Gurux.DLMS.Python 1.0.192
  • Thu, 11/13/2025 - 14:55
    gurux.dlms.java 4.0.84

New forum topics

  • GXTIME Conversion Issue
  • DLMS Meter Gurux DLMS Director Properties
  • Using MAX3232 + FT232RL to Energy meter with GXDLMS Director
  • Incomplete Firmware Upgrade Process
  • SNRM byte mening
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin