Demand register object measures and computes a current average value periodically and it stores a last average value.

Properties

  • 1. Logical Name
    Logical name of the object.
  • 2. Current average value
    Current average value
  • 3. Last average value
    Last average value
  • 4. Scaler and unit
    Used unit and the scaler of the value.
  • 5. Status
    Status information is depending from the object instance.
  • 6. Capture time
    Capture time.
  • 7. Start time current
    Start time current.
  • 8. Period
    Interval between two successive updates of the last average value.
  • 9. Number of periods
    Number of periods.

Actions

  • 1. Reset
    This action is used to reset value to default value.
  • 2. Next period
    Closes the current measuring period.

Book traversal links for Demand register

  • Data
  • Up
  • Disconnect control
  • Log in or register to post comments
  • Create new account
  • Reset your password

Book navigation

  • Activity calendar
  • Association Logical Name
  • Auto Connect
  • Auto answer
  • Clock
  • Compact data
  • Data
  • Demand register
  • Disconnect control
  • Extended register
  • GPRS modem setup
  • GSM diagnostic
  • IEC HDLC setup
  • IEC local port setup
  • IPv4 setup
  • IPv6 setup
  • Image transfer
  • Limiter
  • M-Bus Client
  • M-Bus master port setup
  • M-Bus slave port setup
  • MAC address setup
  • Modem configuration
  • PPP setup
  • Profile generic
  • Push Setup
  • Register
  • Register Monitor
  • Register activation
  • Register table
  • SAP assignment
  • Script table
  • Security setup
  • Single action schedule
  • Special days table
  • Status mapping
  • Tcp Udp Setup
  • Utility tables
  • Manufacturer custom objects

Hire Us!

Latest Releases

  • Tue, 04/14/2026 - 11:47
    gurux.dlms.java 4.0.93
  • Mon, 04/13/2026 - 16:12
    gurux.dlms.java 4.0.92
  • Mon, 04/13/2026 - 11:39
    Gurux.DLMS.Net 9.0.2604.1301
  • Tue, 04/07/2026 - 17:17
    Gurux.DLMS.Python 1.0.197
  • Tue, 04/07/2026 - 15:03
    gurux.dlms.c 9.0.2604.0701

New forum topics

  • FRMR information field translation
  • Connect to EDMI metter
  • Meter rejects reading multiple objects, but it conformance says it supports it.
  • ISKRA ME372 CONNECTION BY DLMSDIRECTOR
  • Connecting To iskrameco ME382- Single Phase Meter with Optical Probe
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin