By icabrera, 3 September, 2024
Forums
DLMSDirector

Hello,

Is it possible to implement in Gurux DLMS Director the interface class IC = 116 ( IEC 62055-41 ) ? You can find in the blue book 15.

It is related with STS prepayment protocol. I have a meter that I want to validate the implementation of class IEC 62055-41.

Thanks.

Profile picture for user Kurumi

Kurumi

1 year 8 months ago

Hi, Yes, it's possible to…

Hi,

Yes, it's possible to add support to IEC 62055-41 Attributes.

I created a task from it:

https://gurux.fi/issue/guruxdlmsnet/25441

It can be released at the end of this month for GXDLMSDirector.

BR,
Mikko

Profile picture for user Kurumi

Kurumi

1 year 7 months ago

Hi, Support for IEC 62055-41…

Hi,

Support for IEC 62055-41 Attributes is added to the GXDLMSDirector version 9.0.2409.1701.

BR,
Mikko

icabrera

1 year 7 months ago

Thanks, it worked well.

Thanks, it worked well.

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 05/11/2026 - 11:07
    Gurux.DLMS.Go 1.0.17
  • Mon, 04/27/2026 - 08:37
    Gurux.DLMS.Go 1.0.16
  • Thu, 04/23/2026 - 13:19
    Gurux.DLMS.Net 9.0.2604.2101
  • Tue, 04/14/2026 - 11:47
    gurux.dlms.java 4.0.93
  • Mon, 04/13/2026 - 16:12
    gurux.dlms.java 4.0.92

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin