I have a problem reading the Iskraemeco meter MT880. Here is my setup:
- manufacturer: Iskraemeco
- Interface: HDLC
- authentication: low
- password: 51525354
- Wait time: 00:00:10
- Address Type: Default
- Logical server: 1
- Media: Net
- Logical Name Referancing - check
- Client Address: 1
- Resend count: 3
- Physical Server: 39 (Serial number: 76959423)
- Media: Net
- Host name: 10.249.11.4
- Port: 4003
- Protocol: TCP
Communication logs:
16:38:17 Send SNRM request.
TX: 7E A0 08 02 4F 03 93 D0 D4 7E
16:38:18
RX: 7E A0 1F 03 02 4F 73 36 BD 81 80 12 05 01 9A 06 01 9A 07 04 00 00 00 01 08 04 00 00 00 01 CC A2 7E
16:38:18 Send AARQ request.
TX: 7E A0 45 02 4F 03 10 15 DF E6 E6 00 60 36 A1 09 06 07 60 85 74 05 08 01 01 8A 02 07 80 8B 07 60 85 74 05 08 02 01 AC 0A 80 08 35 31 35 32 35 33 35 34 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 62 1E 5D FF FF 0B 2F 7E
16:38:18
RX: 7E A0 26 03 02 4F 30 1C 48 E6 E7 00 61 17 A1 09 06 07 60 85 74 05 08 01 01 A2 03 02 01 01 A3 05 A1 03 02 01 0D AE 4F 7E
16:38:18
RX: 7E A0 1F 03 02 4F 73 36 BD 81 80 12 05 01 9A 06 01 9A 07 04 00 00 00 01 08 04 00 00 00 01 CC A2 7E
Error appears:
Connection is permanently rejected. Authentication failure.
What could be the cause of this error? Other Iskra counters that I have read so far have worked on such settings. Is there a default password for reading these counters?
Hi, Your password is not…
Hi,
Your password is not correct. The default password should be on the meter documentation. Iskra meters often use the default password: 12345678.
BR,
Mikko