I would like to know if gurux C or C++ library supports Euridis protocol? Also what is the main difference between DLMS/COSEM and Euridis. I see that Euridis data can be exchanged via without DLMS, with DLMS and with DLMS/COSEM. What is the difference between DLMS and DLMS/COSEM devices?
Hi,
Hi,
Euridis sends DLMS over LPWAN. If your meter is capable to communicate with DLMS and LPWAN you can read your meter using the WRAPPER interface.
DLMS is the same as DLMS/COSEM. COSEM part defined what kind of objects a meter can offer.
List of COSEM objects is available here:
https://www.gurux.fi/Gurux.DLMS.Objects
BR,
Mikko