  2. Meter Rejects Reading Multiple Objects, But It Conformance Says It Supports It.

Meter rejects reading multiple objects, but it conformance says it supports it.

By SMarcin, 22 April, 2026
Forums
Gurux.DLMS

Starting a new thread because i cannot answer in the previous topic:
https://gurux.fi/node/35252

Hello,
I'am trying to read multiple objects with 1 query via tcp/ip using python.

Running this code:

obj1 = GXDLMSRegister()
obj1.shortName = 39656
obj1.attributeIndex = 2

obj2 = GXDLMSRegister()
obj2.shortName = 39800
obj2.attributeIndex = 2

objects = [obj1, obj2]

packets = client.readList(objects)

for p in packets:
reply = send_and_receive(p)
client.getData(reply)

gives me an error:

packets = client.readList(objects)
File "C:\Python313\Lib\site-packages\gurux_dlms\GXDLMSClient.py", line 1255, in readList
raise ValueError(
"Meter doesn't support multiple objects reading with one request."
)

BUT when i connect to the reader using GURUXDLMS Director i get this:

Conformance:
Proposed:
Read, Write, UnconfirmedWrite, MultipleReferences, InformationReport, ParameterizedAccess

Negotiated:
Read, Write, MultipleReferences, ParameterizedAccess

So if i got MultipleReferences in Negotiated conformance i should be able to read multiple objects at once - right?

You asked me for hex trace so here it is:

21:28:20 DEBUG Sending SNRM
21:28:20 DEBUG Received UA: 7ea01e4103738e7f81801205018006013e07040000000108040000000107227e
21:28:20 DEBUG Translation:
<HDLC len="1D" >
<TargetAddress Value="20" />
<SourceAddress Value="1" />
<FrameType Value="73" />
<PDU>
<Ua>
<MaxInfoTX Value="128" />
<MaxInfoRX Value="62" />
<WindowSizeTX Value="1" />
<WindowSizeRX Value="1" />
</Ua></PDU>
</HDLC>

21:28:20 DEBUG Sending AARQ
21:28:20 DEBUG Received AARE: 7ea0374103302179e6e7006128a109060760857405080102a203020100a305a103020100be0f040d0800065f1f04001802200960fa000aa87e
21:28:20 DEBUG Translation:
<HDLC len="36" >
<TargetAddress Value="20" />
<SourceAddress Value="1" />
<FrameType Value="30" />
<PDU>
<AssociationResponse>
<ApplicationContextName Value="SN" />
<AssociationResult Value="00" />
<ResultSourceDiagnostic>
<ACSEServiceUser Value="00" />
</ResultSourceDiagnostic>
<InitiateResponse>
<NegotiatedDlmsVersionNumber Value="06" />
<NegotiatedConformance>
<ConformanceBit Name="Read" />
<ConformanceBit Name="Write" />
<ConformanceBit Name="MultipleReferences" />
<ConformanceBit Name="ParameterizedAccess" />
</NegotiatedConformance>
<NegotiatedMaxPduSize Value="0960" />
<VaaName Value="FA00" />
</InitiateResponse>
</AssociationResponse>
</PDU>
</HDLC>

Profile picture for user Kurumi

Kurumi

2 weeks 5 days ago

Hi, I need the complete hex…

Hi,

I need the complete hex trace, including AARQ, to solve this.

BR,
Mikko

SMarcin

2 weeks 5 days ago

Hello, AARQ: 7E A0 44 03 41…

Hello,

AARQ:
7E A0 44 03 41 10 B3 E1 E6 E6 00 60 36 A1 09 06
07 60 85 74 05 08 01 02 8A 02 07 80 8B 07 60 85
74 05 08 02 01 AC 0A 80 08 30 30 30 30 30 30 30
30 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 1C 03
20 FF FF 0B 87 7E

Which translates to:

<HDLC len="43" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<!-- AARQ frame. -->
<FrameType Value="10" />
<PDU>
<AssociationRequest>
<ApplicationContextName Value="SN" />
<SenderACSERequirements Value="1" />
<MechanismName Value="Low" />
<CallingAuthentication Value="3030303030303030" />
<InitiateRequest>
<ProposedDlmsVersionNumber Value="06" />
<ProposedConformance>
<ConformanceBit Name="Read" />
<ConformanceBit Name="Write" />
<ConformanceBit Name="UnconfirmedWrite" />
<ConformanceBit Name="MultipleReferences" />
<ConformanceBit Name="InformationReport" />
<ConformanceBit Name="ParameterizedAccess" />

SNRM:
7E A0 07 03 41 93 5A 64 7E

Which translates to:

<HDLC len="9" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<FrameType Value="93" />
<Snrm>
</Snrm>
</HDLC>

Profile picture for user Kurumi

Kurumi

2 weeks 4 days ago

Hi, Your objects is wrong…

Hi,

Your objects is wrong.

obj1 = GXDLMSRegister()
obj1.shortName = 39656

list_.append((obj1, 3))

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Mon, 05/11/2026 - 11:07
    Gurux.DLMS.Go 1.0.17
  • Mon, 04/27/2026 - 08:37
    Gurux.DLMS.Go 1.0.16
  • Thu, 04/23/2026 - 13:19
    Gurux.DLMS.Net 9.0.2604.2101
  • Tue, 04/14/2026 - 11:47
    gurux.dlms.java 4.0.93
  • Mon, 04/13/2026 - 16:12
    gurux.dlms.java 4.0.92

New forum topics

  • Error reading L&G Meter
  • Pass a TCP Client to GXNet
  • Australian EDMI Mk10D (Essential Energy area)
  • Strange mix of data notificiation vs get response
  • DLMS Connection
More
RSS feed
Privacy FAQ GXDN Issues Contact
Follow Gurux on Twitter Follow Gurux on Linkedin