  2. Conformance Test: #HDLC_INFO_N3 Failed.

Conformance Test: #HDLC_INFO_N3 failed.

By girija, 5 September, 2024
Forums
Gurux.Serial

Hello Sir,

Recently we got our Smart Gas Meter tested in CTT 4.3 release 103. The meter failed in HDLC_INFO_N3 test, and the report states "Response not RR". The Log is as follow.

TX: 7E A0 07 03 21 93 0F 01 7E
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

TX: 7E A0 2B 03 21 12 E9 8C E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 60 FE DF FF FF DE 4E 7E
RX: 7E A0 07 21 03 97 2B E1 7E

TX: 7E A0 07 03 21 53 03 C7 7E
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

TX: 7E A0 07 03 21 53 03 C7 7E
RX: 7E A0 07 21 03 1F 6B E9 7E

In GURUX DLMD-Director, the test is Passed.
The GXDLMSDirector conformance test logs are as follows.

Meter returns DisconnectMode.
12:37:42 HDLC test #18. SNRMRequest.
TX: 7E A0 07 03 21 93 0F 01 7E
12:37:42
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
12:37:42 HDLC test #18. Wrong N(S) sequence number.
TX: 7E A0 2B 03 21 12 E9 8C E6 E6 00 60 1D A1 09 06 07 60 85 74 05 08 01 01 BE 10 04 0E 01 00 00 00 06 5F 1F 04 00 60 FE 9F FF FF A8 48 7E
12:37:42
RX: 7E A0 07 21 03 97 2B E1 7E
12:37:42 HDLC test #18. SNRMRequest.
TX: 7E A0 07 03 21 93 0F 01 7E
12:37:42
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E
12:37:42 HDLC test #18. Disconnect request
TX: 7E A0 07 03 21 53 03 C7 7E
12:37:42
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

Kindly, guide me!

Regards,
Girija

Profile picture for user Kurumi

Kurumi

1 year 2 months ago

Hi, You need to return RR…

Hi,

You need to return RR. Now you are returning 0x97 that is UnacceptableFrame.

BR,

Mikko

girija

1 year 2 months ago

Hello Sir, I have made the…

Hello Sir,

I have made the necessary changes in code, and the LOG is as follow.

TX: 7E A0 07 03 21 93 0F 01 7E
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

TX: 7E A0 2B 03 21 12 E9 8C E6 E6 00 01 DA 10 90 60 76 08 57 40 50 80 10 1B E1 00 40 E0 10 00 00 00 65 F1 F0 40 06 0F ED FF FF FD E4 7E
RX: 7E A0 07 21 03 31 17 21 7E

TX: 7E A0 07 03 21 53 03 C7 7E
RX: 7E A0 1E 21 03 73 C3 7A 81 80 12 05 01 80 06 01 80 07 04 00 00 00 01 08 04 00 00 00 01 53 3B 7E

Is this correct now?

Regards,
Girija

Profile picture for user Kurumi

Kurumi

1 year 1 month ago

Hi Girija, This is not Wrong…

Hi Girija,

This is not Wrong N(S) sequence number test. The command is wrong, but you ask more data. You need to check that.

BR,
Mikko

  • Create new account
  • Reset your password

Hire Us!

Latest Releases

  • Wed, 10/29/2025 - 08:51
    gurux.dlms.c 9.0.2510.2901
  • Thu, 10/16/2025 - 09:59
    gurux.dlms.java 4.0.83
  • Wed, 10/08/2025 - 10:21
    gurux.dlms.c 9.0.2510.0801
  • Fri, 09/26/2025 - 10:02
    gurux.dlms.cpp 9.0.2509.2601
  • Fri, 09/26/2025 - 09:45
    gurux.dlms.c 9.0.2509.2601

New forum topics

  • How to get/convert user readable format data from readRowsByRange
  • Insufficient memory to continue the execution of the program.
  • The client instance code failed to connect to the electricity meter for authentication
  • Unable to Release Request when closing connection with meter.
  • Failed to receive reply from the device in given time.
More