Is it possible make a request by two or more object at the same time?
For example, if I want recieve, Voltage Inst. value, with Logical Name 1.0.32.7.124.255, and Current Inst. value, with LogicalName 1.0.31.7.124.255.
Is it possible only in one request to the meter?
Hi, It's possible if the…
Hi,
It's possible if the meter is supporting Multiple referencing.
https://www.gurux.fi/Gurux.DLMS.Conformance
You can use readList method to read the values you want. Check readScalerAndUnits method. It'll do exactly what you want to do.
https://github.com/Gurux/gurux.dlms.java/blob/08631c4b144158900b98364e3…
BR,
Mikko
Thanks for answer, I was…
Thanks for answer,
I was able to implement it