NOt able to connect to meter

5 posts / 0 new
Last post
Bhavjinder Singh
NOt able to connect to meter

Below is the trace content coming in the GXDLMSDIRECTOR:

03/07/2018 10:55:45 AM
<HDLC len="9" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<FrameType Value="93" />
<Snrm>
</Snrm>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="9" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<FrameType Value="53" />
<DisconnectRequest>
</DisconnectRequest>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="1E" >
<TargetAddress Value="20" />
<SourceAddress Value="1" />
<FrameType Value="73" />
<PDU>
<Ua>
<MaxInfoTX Value="256" />
<MaxInfoRX Value="128" />
<WindowSizeTX Value="1" />
<WindowSizeRX Value="1" />
</Ua>
</PDU>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="9" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<FrameType Value="93" />
<Snrm>
</Snrm>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="1E" >
<TargetAddress Value="20" />
<SourceAddress Value="1" />
<FrameType Value="73" />
<PDU>
<Ua>
<MaxInfoTX Value="256" />
<MaxInfoRX Value="128" />
<WindowSizeTX Value="1" />
<WindowSizeRX Value="1" />
</Ua>
</PDU>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="43" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<FrameType Value="10" />
<PDU>
<AssociationRequest>
<ApplicationContextName Value="LN" />
<SenderACSERequirements Value="1" />
<MechanismName Value="Low" />
<CallingAuthentication Value="4142434430303031" />
<InitiateRequest>
<ProposedDlmsVersionNumber Value="06" />
<ProposedConformance>
</ProposedConformance>
<ProposedMaxPduSize Value="FFFF" />
</InitiateRequest>
</AssociationRequest>
</PDU>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="2C" >
<TargetAddress Value="20" />
<SourceAddress Value="1" />
<FrameType Value="30" />
<PDU>
<AssociationResponse>
<ApplicationContextName Value="LN" />
<AssociationResult Value="01" />
<ResultSourceDiagnostic>
<ACSEServiceUser Value="01" />
</ResultSourceDiagnostic>
<ConfirmedServiceError>
<Service Value="01" />
<ServiceError>
<Initiate Value="IncompatibleConformance" />
</ServiceError>
</ConfirmedServiceError>
</AssociationResponse>
</PDU>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="1E" >
<TargetAddress Value="20" />
<SourceAddress Value="1" />
<FrameType Value="73" />
<PDU>
<Ua>
<MaxInfoTX Value="256" />
<MaxInfoRX Value="128" />
<WindowSizeTX Value="1" />
<WindowSizeRX Value="1" />
</Ua>
</PDU>
</HDLC>

Bhavjinder Singh
NOt able to connect to meter

It's an indian make meter...

Bhavjinder Singh
NOt able to connect to meter

I have also tried with client address: 10 but no luck.. pls help me

Bhavjinder Singh
NOt able to connect to meter

Hi Mikko.. pls help me..
Im trying to connect meter with GXDLMSDIRECTOR so that i can understand better understand communication.. Meter im reading is of indian make.
but im getting following error in the trace:

<HDLC len="9" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<FrameType Value="93" />
<Snrm>
</Snrm>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="9" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<FrameType Value="53" />
<DisconnectRequest>
</DisconnectRequest>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="1E" >
<TargetAddress Value="20" />
<SourceAddress Value="1" />
<FrameType Value="73" />
<PDU>
<Ua>
<MaxInfoTX Value="256" />
<MaxInfoRX Value="128" />
<WindowSizeTX Value="1" />
<WindowSizeRX Value="1" />
</Ua>
</PDU>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="9" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<FrameType Value="93" />
<Snrm>
</Snrm>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="1E" >
<TargetAddress Value="20" />
<SourceAddress Value="1" />
<FrameType Value="73" />
<PDU>
<Ua>
<MaxInfoTX Value="256" />
<MaxInfoRX Value="128" />
<WindowSizeTX Value="1" />
<WindowSizeRX Value="1" />
</Ua>
</PDU>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="43" >
<TargetAddress Value="1" />
<SourceAddress Value="20" />
<FrameType Value="10" />
<PDU>
<AssociationRequest>
<ApplicationContextName Value="LN" />
<SenderACSERequirements Value="1" />
<MechanismName Value="Low" />
<CallingAuthentication Value="4142434430303031" />
<InitiateRequest>
<ProposedDlmsVersionNumber Value="06" />
<ProposedConformance>
</ProposedConformance>
<ProposedMaxPduSize Value="FFFF" />
</InitiateRequest>
</AssociationRequest>
</PDU>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="2C" >
<TargetAddress Value="20" />
<SourceAddress Value="1" />
<FrameType Value="30" />
<PDU>
<AssociationResponse>
<ApplicationContextName Value="LN" />
<AssociationResult Value="01" />
<ResultSourceDiagnostic>
<ACSEServiceUser Value="01" />
</ResultSourceDiagnostic>
<ConfirmedServiceError>
<Service Value="01" />
<ServiceError>
<Initiate Value="IncompatibleConformance" />
</ServiceError>
</ConfirmedServiceError>
</AssociationResponse>
</PDU>
</HDLC>

03/07/2018 10:55:59 AM
<HDLC len="1E" >
<TargetAddress Value="20" />
<SourceAddress Value="1" />
<FrameType Value="73" />
<PDU>
<Ua>
<MaxInfoTX Value="256" />
<MaxInfoRX Value="128" />
<WindowSizeTX Value="1" />
<WindowSizeRX Value="1" />
</Ua>
</PDU>
</HDLC>

kurumi
kurumi's picture
Not able to connect to meter

Hi,

You have not selected any Conformance. You can see this selecting "Supported services" -tab from device settings.

Select at least Get.

BR,

Mikko

________________________________________
Mikko Kurunsaari
Gurux Ltd
Hermiankatu 6-8 H 33720 TAMPERE, FINLAND
Phone: +358 3 265 1244
Home page: http://www.gurux.org