I want to read historical data from Elster A1500
When I read data In Readout mode and with Optical Port meter is returning to me last 12 reset data like this
But when read with serial port in readout mode meter returns 1 historical data only.
F.F(00000000)
...
...
0.1.0(70) -- > Total Record
...
...
1.8.0(0001340.0*MWh)
1.8.0*70(0001139.2)
..
1.8.1(0000804.2*MWh)
1.8.1*70(0000643.8)
etc..
And When I Want read in programming mode meter returns wrong data
Standart Read
=> /?! CRLF
<= /ABB5\@V4.50
=> <ACK>051 CRLF
<= <SOH>P0<STX>(00391068)<ETX>e
Meter Ident:ABB Elster
=> <SOH>R5<STX>1.8.0()<ETX>^
<= <STX>1.8.0(0001340.0*MWh)<ETX>K
Last Reset Historical Data Read
=> <SOH>R5<STX>0.1.0()<ETX>V -> Total reset
<= <STX>0.1.0(70)<ETX>4 -> Reset Count 70
=> <SOH>R5<STX>0.1.2(70)<ETX>S -> Last Reset Date
<= <STX>0.1.2*70(0307171022)<ETX><US> -> 2017.07.03 17:10:22
=> <SOH>R5<STX>1.8.0(70) -> 70Th 1.8.0
<= <STX>1.8.0(0001340.0*MWh)<ETX>K -> !!!! This is wrong (Must be: 1.8.0*70(0001139.2) !!!!
And Here is a comedy too
=> SOH>R5<STX>0.1.2(69) -> Get then last 2nd data date (69)
<= <STX>0.1.2*70(0307171022)<ETX><US> !!! Whaaat?! !!! (70)
I'm sorry but I can't help you on this. I believe that is best if you ask this from meter vendor.
You are doing everything correctly, so I believe this is depends from the meter.
Read historical data from Elster A1500
Hi,
I'm sorry but I can't help you on this. I believe that is best if you ask this from meter vendor.
You are doing everything correctly, so I believe this is depends from the meter.
BR,
Mikko