By hajikhan, 21 May, 2020 Forums DLMSDirector Hi, I want to read linyang meter with low security do you have any default setting for the same. Thanks, Hajikhan Hi, Hi, Can you select Gurux as a manufacturer and try to read your meter. Use default settings and just set correct serial port or TCP/IP settings. BR, Mikko Hi Mikko, Hi Mikko, Yes I am able to read with default setting but when I am trying to read with low security then I am getting disconnected message from the meter. BR Hajikhan Hi, Hi, Your client address or password is wrong. Try to find from meter manufacturer's documentation if client address is there. You can try to use values 1 and 0x20. BR, Mikko Log in or register to post comments
Hi, Hi, Can you select Gurux as a manufacturer and try to read your meter. Use default settings and just set correct serial port or TCP/IP settings. BR, Mikko
Hi Mikko, Hi Mikko, Yes I am able to read with default setting but when I am trying to read with low security then I am getting disconnected message from the meter. BR Hajikhan
Hi, Hi, Your client address or password is wrong. Try to find from meter manufacturer's documentation if client address is there. You can try to use values 1 and 0x20. BR, Mikko
Hi,
Hi,
Can you select Gurux as a manufacturer and try to read your meter. Use default settings and just set correct serial port or TCP/IP settings.
BR,
Mikko
Hi Mikko,
Hi Mikko,
Yes I am able to read with default setting but when I am trying to read with low security then I am getting disconnected message from the meter.
BR
Hajikhan
Hi,
Hi,
Your client address or password is wrong.
Try to find from meter manufacturer's documentation if client address is there.
You can try to use values 1 and 0x20.
BR,
Mikko