Good afternoon!! I have to ask you. I connect to the Landis & gyr counter through rs 485 moxa. I specify the counter number 1482 and I see that it sends a frame of such content 7e a0 0a 00 02 16 95 21 93 b8 a5 7e. Tell me where it is in this frame number of the counter and which algorithm for calculating the address.
Good afternoon!!! Thank you very much. The second link very helped to understand the technique of calculating the address of the counter. Everything worked out :)
HDLC addresses
Hi,
Your meter is using HDLC framing:
http://www.gurux.fi/GuruxDLMSTranslator?translate=7ea00a000216952193b8a…
You can read more info how to count HDLC address from here:
http://www.gurux.fi/dlmsAddress
BR,
Mikko
Good afternoon!!! Thank you
Good afternoon!!! Thank you very much. The second link very helped to understand the technique of calculating the address of the counter. Everything worked out :)