hi DLMS team,
I want to read daily load profile,but when I read that I am getting the data from the day when I powerup the meter ,I don't want in that manner, I just want to read the daily load of particular date I want to update this profile for every day at 12'o clock.Can you please help to read the profile.
Daily load profile
Hi,
You can use readByRange -method to read data between start and end time.
BR,
Mikko
use readByRange -method
hi ,
I tried like that also but I am getting invalid data .I am sending that log file also,please check that once.
Log created 14:51:16
14:51:20 Read object type ProfileGeneric index: 4
7E A0 19 03 41 32 3A BD E6 E6 00 C0 01 C1 00 07 01 00 63 02 00 FF 04 00 48 C0 7E
14:51:20 Received data
7E A0 15 41 03 52 10 8F E6 E7 00 C4 01 C1 00 06 00 01 51 80 86 0C 7E
14:51:20 Reading profile generic data
7E A0 4C 03 41 54 4B 00 E6 E6 00 C0 01 C1 00 07 01 00 63 02 00 FF 02 01 01 02 04 02 04 12 00 08 09 06 00 00 01 00 00 FF 0F 02 12 00 00 09 0C 07 E1 0C 19 01 00 00 00 FF 01 4A 00 09 0C 07 E1 0C 1A 02 17 3B 00 FF 01 4A 00 01 00 DE B0 7E
14:51:21 Received data
7E A8 89 41 03 74 FF E8 E6 E7 00 C4 02 C1 00 00 00 00 01 00 82 01 E2 01 3D 02 05 09 0C 07 FC 0C 13 FF 00 00 FF FF 01 4A 00 06 17 0F 12 01 06 01 04 66 01 12 0E 12 12 2F 02 02 05 09 0C 00 00 01 01 FF 00 00 FF FF 01 4A 00 06 00 00 00 00 06 00 00 00 00 12 00 00 12 00 00 02 05 09 0C 00 00 01 01 FF 00 00 FF FF 01 4A 00 06 00 00 00 00 06 0B B8 00 C9 12 5A 64 12 0B 0D 02 05 09 0C 00 00 01 01 FF 00 00 FF FF 01 4A 00 0D 7E
14:51:21 Get next frame:
7E A0 07 03 41 71 46 A0 7E
14:51:21 Received data
7E A8 89 41 03 76 ED CB 00 06 00 00 00 00 06 00 00 00 00 12 00 00 12 00 00 02 05 09 0C 00 00 01 01 FF 00 00 FF FF 01 4A 00 06 00 00 00 00 06 00 00 00 00 12 00 00 12 00 00 02 05 09 0C 00 00 01 01 FF 00 00 FF FF 01 4A 00 06 00 00 00 00 06 00 00 00 00 12 00 00 12 00 00 02 05 09 0C 08 3D 01 01 FF 00 00 FF FF 01 4A 00 06 5A 6C 00 00 06 00 00 00 00 12 5A 73 12 00 00 02 05 09 0C 08 43 01 01 FF 00 00 FF FF 01 4A 5F 80 7E
14:51:21 Get next frame:
7E A0 07 03 41 91 48 47 7E
14:51:21 Received data
7E A8 89 41 03 78 93 22 00 06 5A 73 00 00 06 00 00 00 00 12 5A 78 12 00 00 02 05 09 0C 08 6A 01 01 FF 00 00 FF FF 01 4A 00 06 5A 9B 00 00 06 00 00 00 00 12 5A 99 12 00 00 02 05 09 0C 08 4B 01 01 FF 00 00 FF FF 01 4A 00 06 5A 7E 00 00 06 00 00 00 00 12 5A 81 12 00 00 02 05 09 0C 08 63 01 01 FF 00 00 FF FF 01 4A 00 06 5A 90 00 00 06 00 00 00 00 12 5A 95 12 00 00 02 05 09 0C 08 69 01 01 FF 00 00 FF FF 01 4A DF 4A 7E
14:51:21 Get next frame:
7E A0 07 03 41 B1 4A 66 7E
14:51:21 Received data
7E A0 7A 41 03 7A 47 09 00 06 5A 94 00 00 06 00 00 00 00 12 5A 9B 12 00 00 02 05 09 0C 08 42 01 01 FF 00 00 FF FF 01 4A 00 06 5A 74 00 00 06 00 00 00 00 12 5A 6F 12 00 00 02 05 09 0C 08 56 01 01 FF 00 00 FF FF 01 4A 00 06 5A 82 00 00 06 00 00 00 00 12 5A 80 12 00 00 02 05 09 0C 08 53 01 01 FF 00 00 FF FF 01 4A 00 06 5A 83 00 00 06 00 00 00 00 12 5A 86 12 00 00 5B 4E 7E
Daily load profile
Hi,
What meter do you try to read? Date and time value is very strange.
In first row it's 19.12.2044 7:30
BR,
Mikko
Daily load profile
hi,
the meter is L&T meter,I observed that data but why it is like that I don't know ,If I read the all data then it is coming properly.
Daily load profile
Hi,
Are data and time values correctly if you read all the data? You should if meter manufacturer is fixed this.
BR,
Mikko